Size
DC 220V AC 220V
Customized Requirements
Quantity
Stock ( 1693 )

Copy and share this link on social network or send it to your friends

Copy
Product Name 1set 220V AC DC 10A Coil Power Relay DPDT LY2NJ HH62P HHC68A-2Z With Socket Base New
Item NO. 32858801967
Weight 0.07 kg = 0.1543 lb = 2.4692 oz
Category Home Improvement > Electrical Equipments > Relays > Time Relay
Creation Time 2020-10-29

  • Model:LY2NJ
  • Production: Mini Middle Electromagnetic Relay
  • 8Pins 2NO+2NC
  • Current:10A
  • Contacts: Silver plated gold
  • Terminal form: Socket type
  • LED voltage: AC 220/240V DC 
  • Size: 2.6*1.9*4cm /1.02"*0.75"*1.57" (L*W*T)
  • No Retail Packages
  • Quantity: 1SET
  • IMG_0836IMG_0842IMG_0851IMG_0852IMG_0853
  • Rated specification

    Standard type, action indicator built-in coil part /1 pole, 2 pole.

    Rated voltage (V) rated current (mA) coil resistance (_) coil inductance (H) action voltage (V) reset voltage (V) maximum allowable voltage (V) power dissipation (VA, W) 50Hz 60Hz when the iron plate is open. AC122450100/110110/120200/220220/240DC6122448100/110
    106.5 91 46 0.17 0.33 80% below
    *1
     30% Above
    *2
    Rated voltage
    110%
    about 1.0~1.2
    (60Hz)
    53.8 46 180 0.69 1.3
    25.7 22 788 3.22 5.66
    11.7/12.9 10/11 3,750 14.54 24.6 about 0.9~1.1
    (60Hz)
    9.9/10.8 8.4/9.2 4,430 19.2 32.1
    6.2/6.8 5.3/5.8 12,950 54.75 94.07
    4.8/5.3 4.2/4.6 18,790 83.5 136.4
    150 40 0.16 0.33   10% Above
    *2
    about 0.9
    75 160 0.73 1.37
    36.9 650 3.2 5.72
    18.5 2,600 10.6 21.0
    9.1/10 11,000 45.6 86.2

    3pole

    Rated voltage (V) rated current (mA) coil resistance (_) coil inductance (H) action voltage (V) reset voltage (V) maximum allowable voltage (V) power dissipation (VA, W) 50Hz 60Hz when the iron plate is open. AC1224100/110200/220DC122448100/110
    159 134 24 .12 .21 80%below
    *1
    30% Above
    *2
    Rated voltage
    110%
    about1.6~2.0
    (60Hz)
    80 67 100 .44 .79
    14.1/16 12.4/13.7 2,300 10.5 18.5
    9.0/10.0 7.7/8.5 8,650 34.8 59.5
    112 107 .45 .98 10% Above
    *2
    about1.4
    58.6 410 1.89 3.87
    28.2 1,700 8.53 13.9
    12.7/13 8,500 29.6 54.3

    4pole

    Rated voltage (V) rated current (mA) coil resistance (_) coil inductance (H) action voltage (V) reset voltage (V) maximum allowable voltage (V) power dissipation (VA, W) 50Hz 60Hz when the iron plate is open. AC1224100/110200/220DC122448100/110
    199 170 20 0.1 0.17 80% below
    *1
    30% Above
    *2
    Rated voltage
    110%
    about1.95~2.5
    (60Hz)
    93.6 80 78 0.38 0.67
    22.5/25.5 19/21.8 1,800 10.5 17.3
    11.5/13.1 9.8/11.2 6,700 33.1 57.9
    120 100 0.39 0.84 10% Above
    *2
    about 1.5
    69 350 1.41 2.91
    30 1,600 6.39 13.6
    15/15.9 6,900 32.0 63.7

    Note 1. Rated current and coil resistance refer to the coil temperature at +23 C, tolerance AC rated current +15%, - 20%, DC coil resistance of +15%.
    2. the value of AC coil resistance and inductance is the reference value. (60Hz)
    3. the operation characteristic refers to the value of the coil temperature at +23 C.
    4. the maximum allowable voltage refers to the ambient temperature at +23 C.
    *1. products are different, the actual value is less than 80%. In order to ensure normal operation, please add a voltage above 80%. (coil temperature is +23 degrees C)
    The actual value of *2. is below AC30% and DC10% above. To ensure normal reset, please lower the voltage below that value.

    Switch part (contact part)

    Classified 1-pole 2,3,4-pole double-contact resistance load inductive load (cos_ phi = 0.4, L/R = 7ms) resistance load inductive load (cosf = 0.4, L/R = 7ms) resistance load inductive load (cosf = 0.4, L/R = 7ms) contact type contact material rated load current contact voltage maximum contact current contact current
    single double
    Ag alloy Ag
    AC110V 15A
    DC24V 15A
    AC110V 10A
    DC24V 7A
    AC110V 10A
    DC24V 10A
    AC110V 7.5A
    DC24V 5A
    AC110V 5A
    DC24V 5A
    AC110V 4A
    DC24V 4A
    15A 10A 7A
    AC250V
    DC125V
    AC250V
    DC125V
    AC250V
    DC125V
    15A 15A 10A 10A 7A 7A
    Type 1 pole, 2 poles (standard, double contact) 1 pole, 2 poles (action indicator built-in, diode built-in, CR loop built-in) 3 poles, 4 poles use ambient temperature use ambient humidity
    -25 ~ +55 C
    (no icing and condensation) *1 -25 ~ +40 C
    (no ice and dew) *2
    5~85%RH

    Note 1. Limited by the diode junction temperature and the use of components, LY1, 2 series of some models of the use of ambient temperature upper limit value of + 40%.
    2. For use at other temperatures, see Catalog's "Environmental Temperature-Connection Characteristic Data".
    3. When LY1 and PTF08A, PTF08A-E, PT08 are used together and the current is more than 10A, please make short connection between terminals No. 1-2, 3-4 and_-_.
    *1.When the current is below 4A, the ambient temperature is -25 ~ + 70 degrees.
    *2. When the current is below 4A, the ambient temperature is between -25 and + 5.

    performance

    Standard type, built-in action indicator, CR loop built-in, diode built-in double contact resistance * 1 action time * 2 reset time * 2 maximum switching frequency mechanical rated load insulation resistance * 3 withstand voltage coil and junction between different pole contacts with the same pole contact vibration durability Mechanical and electrical *4 failure rate P level (reference value) *5 quality
    50mΩ below
    25ms below
    25ms below
    18,000 times/h
    18,,000 times/h
    100MΩAbove
    AC2,000V 50/60Hz 1min
    AC1,000V 50/60Hz 1min
    10~55~10Hz Single amplitude 0.5mm (double amplitude 1.0mm)
    10~55~10Hz Single amplitude 0.5mm (double amplitude 1.0mm)
    1,000m/s2
    200m/s2
    AC for more than 50 million times.
    DC for more than 100 million times.
    (switching frequency 1800 times /h)
    1, 3 and 4 times 200 thousand times.    
    2 or more than 500 thousand times.
    Rated load switch frequency 1800 times /h)  
    2 or more than 500 thousand times.
    4 or more than 200 thousand times.
    Rated load switch frequency 1800 times /h)
    DC5V 100mA DC5V 10mA
    1, 2 poles are about 40g, 3 poles are about 50g, 4 poles are about 70g.

    Note: the left value is the initial value.
    *1. Measurement conditions: DC5V 1A voltage drop method.
    *2. Measurement conditions: the rated operating voltage does not include contact jumps.

    Ambient temperature conditions: +23 C

    *3. Measurement conditions: use the DC500V insulation resistance meter to measure the same parts in the voltage withstanding project.
    *4. Ambient temperature conditions: +23 C
    *5. This value is the value of switching frequency 120 times /min.

     

     

 

 