MODBUS RTU protocol 4 in 4 out control relay module RS485 switch input and output PLC module

MODBUS RTU protocol 4 in 4 out control relay module RS485 switch input and output PLC module Item NO.: 32881095084

Write a Review
US$ 57.30
Customized Requirements
Quantity
Stock ( 9999999 )

Copy and share this link on social network or send it to your friends

Copy
Product Name MODBUS RTU protocol 4 in 4 out control relay module RS485 switch input and output PLC module
Item NO. 32881095084
Weight 0.3 kg = 0.6614 lb = 10.5822 oz
Category Home Improvement > Electrical Equipments > Relays > Time Relay
Creation Time 2020-10-29

 

Note: the latest batch of product screen printing has been changed from red to blue, and the rest will not change.

 

4 photoelectric isolation input, for dry node input switch quantity, not with voltage.4 10A high current relay output. UseRS485 interfaceThe agreement is used in industry.MODBUS RTU protocol. It can be easily embedded in the RS485 bus.A RS485 bus can be connected to 32 modules.The software set the address and other parameters.The address and other parameters are stored in the EEPROM.Providing control sample source.Standard industrial guideway installation.Anti mistaken design. Electricity without mistake.Providing MODBUS Standard Test Software.Wide power supply 9-24V power supply.The baud rate 1200-19200 can be set up (parity check is not set, no check communication mode).

1. Connection instructions

GND- ----- land(power negative)NO1---- the first set of relays is often open

VCC-------9 to 24V (power cathode)COM1--- first set of relay public end

485A-------RS485 NC1---- is the first group of relay normally closed.

485B-------RS486 negative NO2---- second groups of relay are always open.

IN1-------- first set of switch input COM2---- second sets of relay common end

IN2-------- second sets of switch input NC2---- second relay normally closed.

IN3-------- third sets of switch input NO3---- third groups of relay normally open.

IN4-------- fourth sets of switch input COM3---- third sets of relay common end

NC--------- empty, not using NC3------- third sets of relay normally closed.

NO4------- fourth sets of relays are often open

COM4------ fourth set of relay public ends

NC4------- fourth sets of relays are often closed

 

1.Software protocol

The default baud rate is 9600, one starting bit, 8 data bits, one stop bit, and invalid bit. The default communication address 0x01. The protocol conforms to the MODBUS RTU specification.

Instruction detailed explanation (with address 1 as an example)

1, read the switch quantity input.

Send instruction format: Address (1 byte) + command (one byte) + register address (two byte) + data field (two byte) +CRC check code (two bytes).

Data return format: Address (1 bytes) + command (one byte) + return byte number (1 bytes) + returned data (one byte) +CRC check code (two bytes)

Send out01 02 00 20 00 04 78 03

Return01 02 01 0F E1 8C

returnreturn0F,Only low 4 bits of this module are only concerned about low four bits. From the first to the firstThe 4 bit indicates the state of the switch input from INPUT1 to INPUT4 respectively. When the input signal is switched on, the corresponding bit is 0. If the first switch volume has input, the other road has no switch input and this value is 0E.

 

2,Control the output of the relay.

2.1 control the operation of a single relay at a time (assuming the module is 0x01).

Open the first road 01 05 00 10 FF 00 8D FF

 

Open second ways 01 05 00 11 FF 00 DC 3F

Open third ways 01 05 00 12 FF 00 2C 3F

Open fourth ways 01 05 00 13 FF 00 7D FF

The first road 01 05 00 10 00 00 CC 0F

Close second road 01 05 00 11 00 00 9D CF

Close third road 01 05 00 12 00 00 6D CF

Close Fourth Road 01 05 00 13 00 00 3C 0F

The command returned by the above command is the command sent.

 

2.2 operation of all relay actions

Open all01 0F 00 10 00 04 01 0F BF 51

 

Close all01 0F 00 10 00 04 01 00 FF 55

Set one or two roads and set three or four pass01 0F 00 10 00 04 01 03 BF 54

Set one or two roads, set three or four and open 01 0F 00 10 00 04 01 0C FF 50

 

The above command returns all01 0F 00 10 00 0455 CD

 

3.Read the output state of the relay

Send outInstruction latticeType: Address (1 byte) + command (one byte) + register address (two byte) + data field (two byte) +CRC check code (two bytes).

Data return format: Address (1 bytes) + command (one byte) + return byte number (1 bytes) + returned data (one byte) +CRC check code (two bytes)

Send out01 01 00 10 00 04 3C 0C

Return01 01 01 00 51 88

returnBack 00, output relay state, 0 is disconnected, 1 is suction. This module only uses 4 bits, only cares about four bits low..

4,Setting the module address

takeChange the device address to01: 00060001000118 1B

 

takeChange the device address to02: 00060001000258 1A

5. Amend the baud rate

The modified baud rate is 1200: send 000600020001E8 1B

The modified baud rate is 2400: send 000600020002A8 1A

The modified baud rate is 4800: send 00060002000369 Da

The modified baud rate is 9600: send 0006000200042818

Modify the baud rate to 19200 send 000600020005E9 D8

After the modification, the same data will be sent back, and then the device is recharged, that is to complete the modification. When the baud rate is forgotten, the baud rate of the serial port and transceiver can be set respectively from 1200 to 19200. When the baud rate is modified, only one device can be connected.

 

This product can definitely connect to PLC. We know that PLC supports MODBUS RTU protocol, and the following is the Modbus Poll test communication using MODBUS's test software.

Control relay

 

Read switch quantity

Provide C++ reference code design, the following is the interface to provide reference program.

The interface provides source code, powerful, able to modify the device's address, to operate the various relays, and to read the switch input, and to read whether the relay is absorbing or closing. It can also calculate the CRC check value, and can display the data returned by the device. This software can be used to test the equipment directly in the installation process, so that the installation personnel can test the installation of the equipment immediately after installation, which greatly facilitates the installation and maintenance of the equipment.

Physical map

 

 

 