Product Name T2302 12V Timing Delay Timer Relay Module Digital LED Dual Display Cycle 0-999 Hours 20A
Item NO. 32976456057
Weight 0.04 kg = 0.0882 lb = 1.4110 oz
Category Home Improvement > Electrical Equipments > Relays > Time Relay
Creation Time 2020-10-29

RM13262996453376857

Technical Parameters

Product Name: T2302 Time Digital Relay

Working voltage: DC12V

Relay: 20A

Timing range: 0-999 seconds, 0-999 minutes, 0-999 hours

Working mode: delay on, delay off, timing on, timing off, cycle on, cycle off

Size: 45.5mm × 26.5mm × 30mm


Product Instructions

Please pay attention for your first use. You need wait 6s after your setting data, the module will save the date you have set after 6s.  

Short press button SET: If you start the time setting mode , Nixie tube will blink. You could adjust the time T1 and T2 by button+ and button-. Please wait 5s after your setting date, the module will save the date you have set after 5s .

 

Long press button SET: if you start the parameter setting mode. There are two group parameter for your choice  : P0 and P1. You could switch P0 or P1 by short press SET. Under the parameter P0 and P1,you could set the timing mode by the button+ and button-.

 

P0--0: Timing time mode : 0---999s.

P0--1: Timing time mode : 0---999min.

P0--2: Timing time mode : 0---999h.

P1--0: The relay will connect after you delay the T1 time .

P1--1: The relay will disconnect after you delay the T1 time.

P1--2: The relay will connect after you delay the T1 time first, Then the relay will disconnect after you delay the T2 time , it finish.

P1--3: The relay will disconnect after you delay the T1 time first, Then the relay will connect after you delay the T2 time , it finish.

P1--4: The relay will connect after you delay the T1 time  first, Then the relay will disconnect after you delay the T2 time , it is cyclic.

P1--5: The relay will disconnect after you delay the T1 time first, Then the relay will connect after you delay the T2 time , it cyclic.

Example: A customer needs 10 seconds to start up and 20 seconds off. Setup is as follows:

T1 set time 10, T2 set time 20

P0 -- 0 (T1 time range is seconds)

P1--5 (timer work mode)

 

Package Include: